Explore BrainMass
Share

Explore BrainMass

    Thermistor connected to ADC

    This content was COPIED from BrainMass.com - View the original, and get the already-completed solution here!

    A thermistor is used to monitor the temperature of the cooling air to a motor control unit. The air temperature must remain in the range 0 degree Centigrade to 70 degree Centigrade for correct operation. The thermistor is connected to a 12-bit ADC as shown in Figure A3 in the attachment.

    (i) What are the maximum and minimum codes from the ADC (in hexadecimal), which correspond to the extremes of the temperature range?
    (ii) If the output from the ADC is (7A4)Hex, what is the temperature in degree Centigrade?

    See attached file for full problem description.

    © BrainMass Inc. brainmass.com April 3, 2020, 1:29 pm ad1c9bdddf
    https://brainmass.com/physics/temperature/thermistor-connected-adc-2379

    Attachments

    Solution Preview

    Please see attached file.

    A3

    (a) A thermistor is used to monitor the temperature of the cooling air to a motor control unit. The air temperature must remain in the range 00C to 700C for correct operation. The thermistor is connected to ...

    Solution Summary

    Calculations are shown stepwise, along with a brief mention about how this problem is approached.