Calculate efficiency of sewage treatment
Not what you're looking for?
A sewage treatment plant influent has a BOD5 value of 310 mg/L. What efficiency must the treatment plant have in order to meet the NPDES BOD5 requirement of less than 30 mg/L? Will this sewage treatment plant need a tertiary treatment stage?
Purchase this Solution
Solution Summary
The percentage of efficiency needed to meet the required BOD5 values is calculated for a sewage treatment plant.
Solution Preview
% efficiency =[ (310 - 30) / 310] x 100 = 90.32%
Tertiary treatment is ...