Purchase Solution

Gas Absorption and Transfer Operations: Column Diameter Calculation

Not what you're looking for?

Ask Custom Question

A gas absorption column to handle 3630 kg/hr of a gas is being designed. Based on pressure drop, entrainment and foaming considerations, the maximum vapor velocity must not exceed 0.61 meters/sec. If the density of the vapor is 0.801 kg/m^3, what is the column diameter?

Purchase this Solution

Solution Summary

The column diameter is calculated given a gas absorption rate.

Solution Preview

The column cross sectional area can be calculated as follows..

Area = (Vapor flow rate) / (vapor ...