    A vapor-compression heat pump system

    This content was COPIED from BrainMass.com - View the original, and get the already-completed solution here!

    A vapor-compression heat pump system uses R-134a as the working fluid. The refrigerant enters the compressor at 0.24 Mpa, 0 degrees Celsius, with a volumetric flow rate of 0.6m^3/min. The compression process is adiabatic to 0.9 MPa, 60 degrees Celsius, and saturated liquid exits the condenser at 0.9 MPa.
    Find the following:
    a.) The power input to the compressor, in kW.
    b.) The heating capacity of the system in kW (Qout)
    c.) The coefficient of performance
    d.) The compressor's isentropic efficiency.