Explore BrainMass

Explore BrainMass

    Fabry-Perot interferometer

    Not what you're looking for? Search our solutions OR ask your own Custom question.

    This content was COPIED from BrainMass.com - View the original, and get the already-completed solution here!

    A Fabry-Perot interferometer is to be used to resolve the mode structure of a He-Ne laser operating at 632.8 nm. The frequency separation between the modes is 150 MHz. The plates are separated by an air gap and have a reflectance (r^2) of 0.999.
    (a) What is the coefficient of finesse of the instrument?
    (b) What is the resolving power required?
    (c) What plate spacing is required?
    (d) What is the free spectral range of the instrument under these conditions?
    (e) What is the minimum resolvable wavelength interval under these conditions?

    © BrainMass Inc. brainmass.com March 4, 2021, 8:58 pm ad1c9bdddf
    https://brainmass.com/physics/mirrors/fabry-perot-interferometer-207320

    Solution Preview

    fabry perot interferometer
    A Fabry-Perot interferometer is to be used to resolve the mode structure of a He-Ne laser operating at 632.8 nm. The frequency separation between the modes is 150 MHz. The plates are separated by an air gap and have a reflectance (r^2) of 0.999.
    , , ...

    Solution Summary

    The solution calculates the parameters of a Fabry-Perot interferometer.

    $2.49