Calculate S, complex power of a load (in rectangular form), given the following data:
magnitude of S = 600 VA; Q = 450 VAR (inductive). See attached file for full problem description.
Purchase this Solution
Solution Summary
The problem has been solved first explaining the fundamental principles involved.
Solution Preview
Please see the attached file.
SOLUTION
Total power of a reactive load can be expressed as :
S = VI cosθ + j VI sinθ where V and I are rms values of voltage and current and θ is the phase angle. ............(1)