Calculating the Maximum Volume of Fermentor that can be used without Additional Cooling

Not what you're looking for?

Ask Custom Question

The heat generated by fermentor is 60 kcal/hr L. The cooling capacity of jacket is 10,000 kcal/hr m^2. For a cylindrical fermentor with H/D of 3, the jacket area (m^2) is porportional to fermentor volume (m^3) to the 2/3 power.

Area of Jacket (m^2) = 7*v^(2/3) (m^3)

What is the maximum volume of the fermentor that can be used without additional cooling capacity?

Purchase this Solution

Solution Summary

Using equalites relating heat generated and heat removed, the maximum volume of the fermentor that can be used without additional cooling is calculated. The calculation steps are shown.

Solution Preview

The heat generated by a fermentor with volume v [L] is

Qgen=60*v ...